Project index | Parameter index |
Input Power | AC 380V ±10% / 50Hz |
Resolution | AD: 16bit; DA: 16bit |
Input Resistance | ≥100kΩ |
Input Power | 5316W |
Voltage | Constant voltage range control | 0.025V~5V |
Minimum discharge voltage | 2V |
Accuracy | ± 0.1% of FS |
Stability | ± 0.1% of FS |
Current | Per Channel Output Current Range | 0.75A~150A |
Accuracy | ± 0.1% of FS |
Constant voltage cut-off current | 0.3A |
Stability | 0.1% of FS |
Power | Maximum output power of single channel | 750W |
Stability | ± 0.2% of FS |
Time | Current Response Time | Maximum current rise time 20ms |
Step Time Range | ≤(365*24) hours; time format supports 00:00:00.000 (h, min, s, ms) |
Data Recording | Record Condition | Time△t:100ms |
Voltage△U:10mV |
Current△I:300mA |
Record Frequency | 10Hz |
Charge | Charge Mode | Constant Current Charge、Constant Voltage Charge、 CC-CV Charge 、CP-Charge |
End Condition | Voltage、Current、Relative Time、Capacity、-△V |
Discharge | Discharge Mode | Constant Current Discharge CP-D CR-D |
End Condition | Current、Current、Relative Time、Capacity、-△V |
Pulse Model | Charge | Constant Current、Constant Power |
Discharge | Constant Current、Constant Power |
Min Pulse Width | 500ms |
Pulse Number | Single Pulse Step Support 32 different Pulse |
Continuous switching between charge and discharge | One pulse step can realize continuous switching from charging to discharging |
Stop Condition | Voltage, Relative Time |
DCIR Testing | Support Custom Access Point And Count The DCR |
Parallel mode | Up to 4 channels can be connected in parallel, and pulse and analog tests are not supported after paralleling |
Cycle | Loop Measure Range | 1~65535 times |
Max Steps Per Loop | 254 |
Nested Loop | Nested loop Function,Max Support 3 Layers |
Protection | Power-down data protection |
With offline test function |
Safety protection conditions can be set, setting parameters include: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, delay time |
With anti-reverse connection function (need to cooperate with software) |
IP protection level | Protection grade IP20 |
Channel characteristics | Constant current source and constant voltage source adopt double closed loop structure |
Channel control mode | Independent control |
Voltage and Current Testing Sample | 4-wire connecting |
Noise | <75dB |
Data Management | MySQL Database |
Communication Means | TCP/IP Protocol |
Server disk configuration | 500GB |
Data Output | EXCEL 2003,2010, TXT |
Server operating system | Windows 7, Windows 10 |
Communication Interface | Network port |
Equipment working environment requirements |
Index item | Index parameter |
Range of working temperature | 0℃~40℃ (within the range of 25±10℃, the measurement accuracy is guaranteed: accuracy drift 0.005% of FS /℃) |
Storage temperature range | -10℃~50℃ |
Relative humidity range of working environment | ≤70% RH (no condensation) |
Storage environment relative humidity range | ≤80% RH (no condensation) |
Clamps specifications and dimensions |
Index item | Index parameter |
Clamps type | Alligator clamps |
Picture of clamps | |
| |
Alligator clamps | Polymer clamps | Button clamps |
The picture is for reference only, subject to the actual product, selectable |
Main Channels | 4 |
Dimensions | 18U(19”),600*600*1000 per unit |
Auxiliary channel (plus 100K input impedance) | Auxiliary channel type | Temperature |
Temperature range | -50℃~110℃(Thermistor) |
Temperature accuracy | ±1℃ (line length within 2m) |
Temperature resolution | 0.1℃ |
Auxiliary channel protection conditions | The auxiliary channel protection conditions can be set, and the parameters that can be set include: upper temperature limit, lower temperature limit |
Remarks: Not compatible with the test of battery with protection board with soft-start function |